Lighting - Display/Keyboard Light & Contrast
Control
There are two basic display setups. The light function key
allows you to instantly switch between two predefined
screens (Daylight & Nightlight).
Log - Speed Log Input (Pulse or NMEA 0183)
This screen controls the input port (NMEA-0183 or Pulse)
and format of the speed log input to the receiver. In the
default condition, the speed log is not connected. NMEA
0183 speed is accepted from the xxVHW data sentence
originating in any of the version 1.5, 2.0, 2.1, or 2.3
format where xx is a valid talker ID as specified in the
NMEA 0183 standard. The receiver will also accept speed
log pulse input, with pulses of up to 1.5 kHz. Refer to the
Installation section of this manual for the wiring interface
instructions.
NMEA 0183 /VHW) Input Screen Pulse Input Screen
NMEA Input
Data Input Port No. - Select the appropriate NMEA input
port as determined by the hardware interface. Refer to
the Appendix F of this manual for wiring connections.
Alarm If No Data - Causes an alarm to activate if data is
not received on the port you defined within 10 seconds
when Yes is selected (the default condition). To disable
the alarm, select No with the Change softkey.