Appendix C - Multiple unit control | 151
Appendix C - Multiple Unit Control (Via LAN)
Dual Control Conguration:
The Dual Control mode allows you to connect one MX51x as a Master and another MX51x
as a Slave unit. This allows a common data base to be shared between the two CDU
control heads. This configuration also allows you to use one antenna connected to the
Master unit for both CDUs. The remaining data ports, the MOB/Event input port, and the
alarm output ports are still available on each unit for individual use on each CDU.
The hardware interface is accomplished by connecting the two units together via the
Local Area Network (LAN) port. You can use an Ethernet cross-over (null) cable or a LAN
hub (or Ethernet switch). Refer to page 77 of this manual to setup LAN.
The interface between the two units takes place over a high speed (100 Mbps) data link.
The master unit must be connected to the antenna. The master unit receives the NMEA
signals from the smart antenna and pass it along to the slave unit. Due to the high speed
data link, there is virtually no visible position delay between the two units.
When the two units are first configured as master and slave, the master unit mirrors
to the slave, and the Common Data Base (see Table D-1) is downloaded from the
master to the slave. This function also takes place each time the units are powered up.
If you happen to have the CFG1 Dual Control screen active, the status bar will indicate
Mirroring during the database update period.
Data Base Comments
Present Position Update once per second
Time Update once per second. Displayed in the same mode on both units
Date
Routes Only one unit can make changes at any given time
Waypoints Only one unit can make changes at any given time
Reset XTE Only one unit can make changes at any given time
DGPS SEtup Only one unit can make changes at any given time
Dual Control Alarms
Man Over Board Only one unit can make changes at any given time
Table D-1. Master/Slave Common Database
The items detailed in Table D-2 are independently controlled at the individual CDU heads.