164 | Appendix E - AIS connection for MX512 only
Note: A total of 35 lines are available under the AIS Static menu. If only 10 lines
are available when you scroll down, the MX512 may not be communicating with the
transponder. Verify that the “AIS Connected” value is set to YES and the correct
transponder type is selected.
Display Field Descriptions:
AIS, ECDIS, PILOT, Long Range, Ext. GPS Connected:
Highlight the
softkey then press the ENT key to select Yes or No. Yes means that
the selected unit is connected to the MX512.
ECDIS, PILOT, Long Range, Ext. GPS Port:
Use the
softkey to select the serial port number to which the device is connected.
AIS Port” is pre-selected to NMEA5, Long-Range Communication port is NMEA 9, ECDIS
is on NMEA 10 and the Pilot port is on NMEA 7.
ECDIS and PILOT Msg Config:
Use the
softkey to select between IEC or PAIS protocol for the communication
standard used with the associated device. IEC protocol is preferred for most AIS
interface.
Long Range Reply:
Use the
softkey to select between AUTO, Manual or Off. In Manual mode, the
user is prompted to reply to the Long-Range system when interrogated. In Auto mode,
the MX512/AIS automatically sends a reply when interrogated. In Ext. Appl (External
Application) mode, the MX512/AIS passes the request onto the high-speed ports (ECDIS
& Pilot), and waits for their response to prepare answer back to long range system.
MMSI:
A unique 9-digit Maritime Mobile Service Identity number used for identification of ship
and message (administrator password required).